SUNISO Refrigerant OIL Fully synthetic Oil HFC OIL3GSD 4GSD 5GSD

Categories Refrigerant Oil
Brand Name: SUNISO
Model Number: 3GSD 4GSD 5GSD
Place of Origin: CHINA
MOQ: UNITS
Price: USD8-2500
Supply Ability: 50000UNITS 15DAYS
Delivery Time: 3-15DAYS
Packaging Details: UNITS
SUNISO 3GS: Pour point ℃-40
SUNISO 4GS: Pour point ℃-35
SUNISO 5GS: Pour point ℃-27.5
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    SUNISO Refrigerant OIL Fully synthetic Oil HFC OIL3GSD 4GSD 5GSD

    TEMPERATURE AND PRESSURE

    Oil temperature generally keep between 45 ~ 60 ℃, the highest should not be more than 70 ℃, and stable, if the oil temperature has been unstable and slowly rising, then have a fault.The oil temperature too low or too high will worsen lubricating oil, at the same time, also often heralds the arrival of the predicted failure.Key is refers to the oil pressure difference, frozen oil pressure due to various reasons cause oil pump oiling, is can't afford to build oil pressure difference.Oil pressure size according to the structure of the compressor.Vertical compressor of external gear oil pressure difference is 0.5 ~ 1.5 MPa, the new series compressor oil pressure difference is 0.5 ~ 1.5 MPa.New purchase of compressor in operation, debugging using oil pressure difference often on the high side, in order to increase the amount of lubricating oil, better finish the moving parts such as cylinder period, prolong the service life of the machine..


    Typical projectTest method forSUNISO 3GSSUNISO 4GSSUNISO 5GS
    The density of 15℃g/cm3ASTM D 12500.9090.9150.921
    chroma ASTMmm2/sASTM D 1500L0.5L1.0L1.0
    Kinematic viscosity 40℃mm2/sASTM D 44529.554.994.6
    Kinematic viscosity 100℃ASTM D 4454.315.977.78

    Flash point

    COC℃

    ASTM D 92178188208

    Pour point

    ASTM D 97-40-35-27.5
    The total acid value mg KOH/gASTM D 9740.010.010.01

    Aniline point

    ASTM D 61175.479.880.4

    The moisture

    ppm

    ASTM D 4928202020

    Floc point

    ANSI/ASHRAE 86-53-46-35


    Refrigeration cycle system on the properties of frozen oil requirements

    Refrigeration cycle systemThe performance requirements


    The compressor

    The condenser

    Expansion valve

    Steam trap

    • And refrigeration coexist with excellent chemical stability
    • have good lubricity
    • Has excellent intermiscibility with refrigerant
    • the insulation and sealing material has excellent adaptability
    • Have a good anti-foam properties
    Have a good intermiscibility with refrigerant
    • no wax flocculation separation
    • No water
    • has excellent low temperature fluidity
    • no wax flocculation separation
    • No water
    • Have a good intermiscibility with refrigerant

    The classification of the refrigerant and frozen oil

    projectASHRAE nameName of commodityChemical name and chemical formulaFrozen oil
    Cfc-free refrigerants
    And frozen oil

    R 134a

    R 507

    R 404A

    R 407C

    R 410A

    R 600a/R 290

    R 717

    R 744

    Diverse

    Solkane 507,AZ50

    Diverse

    Diverse

    Solkane 410,AZ50

    Isobutane/propane
    ammonia
    Carbon dioxide

    CH2FCF3

    R 125/R 143a

    R 125/R 143a/R134a

    R 32/R 125/R 134a

    R 32/R 125

    C4H10/C3H8

    NH3

    CO2

    POE,PAG

    POE

    POE

    POE

    POE

    MO/AB

    MO/PAO/AB

    Synthetic oil

    Drop-Inrefrigeration
    Agent and freezing oil

    R 22

    R 401A

    R 401B

    R 402A/B

    R 403A/B

    R 408A

    Diverse

    MP 39

    MP 66

    HP 80/81

    69 S/L

    FX 10

    CHCIF2

    R 22/R 152a/R 124

    R 22/R 152a/R 124

    R 22/R 125/R 290

    R 22/R 218/R 290

    R 22/R 143a/R 125

    MO/AB

    MO/AB

    MO/AB

    MO/AB

    MO/AB

    MO/AB

    • AB oil for alkyl benzene;MO mineral oil;PAG for poly (alkyl) glycol;PAO for poly alpha olefins;POE for oil polyols.
    • try products: POE, PAG, etc.

    HFC refrigerant and frozen oil

    Machinery and equipmentSubstitute HFC refrigerantsMatch the types of refrigeration oil
    Automotive air conditioningR 134aPolyethylene glycol (peg)

    The refrigerator reciprocating

    rotary

    R 134a

    R 134a

    Polyester

    Alkyl benzene

    The low temperature equipmentR 404A/R 507Polyester, polyethylene ether

    Air conditioner Split type

    window

    R 410A

    R 407C

    Polyester, polyethylene ether,

    alkyl benzene
    Polyester, polyethylene ether

    Different refrigerants for refrigeration oil types

    refrigerantR 12R 22R 134aammoniaR 600aDry straight cold
    industrialcarnormalDry straight cold
    Refrigerator oil typeMineral oilMineral oil,
    Alkyl benzene,
    esters
    estersPAGMineral oilPAGEsters, mineral oil,PAGPAG,esters

    All kinds of refrigeration oil performance contrast

    Naphthenic base oil frozen

    Naphthenic base oil chemical stability frozen, not with refrigerant or other materials react to exist in the system.Its thermal stability is good, in the hot section of the discharge valve does not accumulate carbon sediment.Wax content is low, in the cold parts of the system, can prevent oil and refrigerant mixture flocculent precipitate on the surface of wax and block system.Low pour point, preventing oil precipitation and solidification in the pipe.Dielectric insulation intensity is high, can ensure good insulation performance.Oil viscosity is moderate, were diluted with coolant can still keep the strength of the oil film lubrication.At the same time, in a very low temperature conditions, can still maintain liquidity.Applicable to the R11, R12, R13B1, R113, r22®, R114, R600a refrigerant, etc.

    Ester synthesis freezing oil

    good sealing, and can provide good lubrication in the middle of the bearing and sealing elements.Under low temperature condition, with good solubility and ensuring that the oil bath evaporator good oil return, and has good heat exchange efficiency.In addition, but also has very low volatile and good oil and gas separation.

    Polyether type synthetic refrigeration oil

    temperature range, and everything has excellent solubility, won't produce phase separation, can improve the working efficiency of the compressor.Compared with other products, such as polyol ester will produce the series of problems, such as corrosive acid and PAG even when exposed to high temperature and high humidity environment, rarely produce degradation.

    Alkyl benzene synthetic refrigeration oil

    Fully synthetic alkyl benzene frozen oil, has good low temperature property, oxidation stability and thermal stability.Suitable for CFC, as, carbon dioxide and ammonia as refrigerant air conditioning and refrigerating machine, etc, also can be used with contain as mixed refrigerants.

    Freezer lubricating failure and countermeasures

    (1)Lubrication oil pump pressure, pressure regulating failure and violent oscillation pressure gauge pointer

    • Freezer lubricating system normal work is: the main oil pressure gauge indicating stability;In the crankcase oil temperature should be kept between 10 to 65 ℃, optimum working temperature of 35 to 55 ℃;In the crankcase oil level should be high enough, and should be stable for a long time.Oil filter filter should not be blocked and differential pressure transmitting of fine oil filter should be blocked transmitting instructions.
      Lubrication oil pump pressure, pressure regulating failure and pressure gauge pointer violent oscillation, the main reason is: the CPC temperature is too low, crank case, refrigerator oil pump imported oil filter mesh, filter blocked, and the oil level is too low, the oil pump oil absorption is difficult, empty absorption phenomenon;Oil pump work for a long time, the wear of the pump is serious, internal leakage is too large, significantly lower volume effect;Pressure regulating valve core is stuck in the open position or pressure regulating valve spring failure;Serious leakage system.
      In order to solve the above problems, can take the following measures:
    • according to provisions of frozen oil index of oil change regularly check oil, replace or supplement the new oil filter.
    • regular replacement or cleaning filter, pipeline and crankcase.
    • Observed in daily check the oil level, oil temperature, oil pressure is normal.
    • Which should be paid attention to when, overhaul in the check and adjust the end clearance of oil pump, the pump should be replaced when necessary.Pump end clearance of different depending on the size of the product standard is about 0.03 ~ 0.08 mm, specific values and see about pump assembly technology requirements and delivery requirements.

    (2)Ice plug" phenomenon and prevent the refrigeration system

    Ice jam phenomenon was due to freon system for various reasons and mixed with water, where the temperature is lower than 0 ℃ ice, causing pipeline clogging. When the "ice plug", expansion valve of high pressure liquid refrigerant, cannot pass ball valve and evaporate into low pressure, low temperature evaporation of refrigerant. In this way, too cold steam evaporator is not enough, of course there would be no air conditioning sent out.
    "Ice plug" is due to the moisture into the air conditioning system.Refrigerator oil mixed with water, in addition to causing viscosity is reduced, cause corrosion to metal, will there be any freon refrigeration system cause the phenomenon of ice jam.
    Such as improper operation of maintenance, vacuum is not complete, and the moisture content is more in the refrigerant or frozen oil, can make water into the system.In order to remove moisture, installed on the system for liquid filter drier, the small amount of water in the desiccant can be absorbed into the system.But if too much water into the system, can disable desiccant, resulting in "ice".


    The quality :
    Guarantee the original quality goods, oil test report, the product COA certificate;
    Reasonable price:
    Scattered order centralized processing, factory direct supply - save procurement cost;

    More than the spot:
    First-class warehousing logistics system, commonly used models of a large number of inventory, the goods time saving;

    Strong professional:
    Strong professional after-sale technical team, precise check product data model, can undertake projects - province saliva, let data speak;
    Logistics fast;
    Without the blind spots distribution of the country, Shanghai, guangzhou, wuhan, chengdu, zhengzhou, lanzhou, the northeast have a high quality partners can be the nearest distribution;

    -------------------------------------------------------------------------------------------------------------------------------

    Shopping guidelines
    Because of frozen oil products and type is various, can't list all products and models, if there is demand for other models, please contact customer service.

    Cheap SUNISO Refrigerant OIL Fully synthetic Oil HFC OIL3GSD 4GSD 5GSD for sale
    Send your message to this supplier
     
    From:
    To: HUIZHAN ENERGY MACHINERY CO., LTD
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2019 xuijs.com. All rights reserved.