2 Inch Clamp Type Electromagnetic Flow Meter for Waster Water Field

Categories Electromagnetic Flow Meter
Model Number: MTF
Certification: CE/CMC/ISO9001
Place of Origin: China
MOQ: 1pc
Price: negotiation
Payment Terms: T/T or western Union
Supply Ability: 100pcs per month
Delivery Time: 7 working days after received your payment
Packaging Details: in wooden box
Brand Name: Metlan
Product Name: Clamp Type Electromagnetic Flow Meter for waste water
Application: Environmental protection area.
Diameter: DN50mm
Accuracy: ±0.2% ±0.5%
Protection level: IP65
Output signal: 4-20mA,pulse,RS485/Hart
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    2 Inch Clamp Type Electromagnetic Flow Meter for Waster Water Field

    2 Inch Clamp Type Electromagnetic Flow Meter for

    Waste Water Field


    Application:

    MTF electromagnetic flow meter is, a kind of
    instrument,used for measuring the flow conductivity liquid,
    which is widely used in flow measuring of Metallurgy, Chemical
    industry, Paper industry, Environmental protection, Oil industry,
    Textile industry, Food industry and City administration, Water
    works,etc.



    Instrument characteristics


    1). No baffles and running part inside the measuring tube,
    therefore no additional flow loss and no jams happen.
    Especially for measuring the flow of solid-liquid object, for
    example, sewage, mud pulp and CWS (coal water slurry).


    2). Only liner and electrode have direct contact with the
    measuring medium, by choosing correct liner and
    electrode,,then the corrosion resistance and wear resistance
    can be satisfied. Therefore it can be used in kinds of strong
    acid and alkali in chemical solutions.


    3). Easy for installation, 5D for front straight pipe, 2D for back
    straight pipe(D means inner diameter of chosen instrument).
    4).High accuracy, it is up to ±0.2%, it is capable for testing

    forward/reverse Bi-directional flow.


    5). Dual frequency excitation is adopted to avoid the affection
    from public frequency.


    6). Low consumption.


    7). Good interchangeability of the converter, it is easy to have
    the accuracy without remark the real flow.


    8). Wide ranges.



    Instrument detection and maintenance


    Electromagnetic flow converter has self-diagnosis function. In addition to the power and hardware circuit fault, The system also give alarm to other faults in general usage. These information are given accordingly prompts in the lower right of the screen.


    1, Maintenance and repair


    a) Sensor installation site should be consistent with the section four requirements,

    Please keep the housing clean and tidy


    b)Transmitter should be placed in a clean, ventilated, dry place

    c) Need to inspect every two years, for high precision users, instrument need to be submitted to censorship.


    2, Transportation, storage
    a) The instrument must be packed before transportation, be carefully handled when loading and unloading.
    b) Storage site must be dry, ventilated, avoid corrosive gas erosion, the ambient temperature is not too low or too high.

    c) Storage time better not exceed three years.


    3, Unpacking and checking

    a) The packing can’t be opened with heavy hammer, and should be careful not to damage the instrument





    Data Sheet


    MTF
    Electromagnetic
    flow meter

    Divided type

    Integrated
    type(IP67)

    Explosion-
    proof
    integrated

    Battery
    powered
    type

    Heat(energy) type

    Accuracy

    ±0.2% or ±0.5%

    Diameter

    DN15~dn2400

    DN15~DN600

    DN25~DN1400

    Flange

    Comply with GB9119 Standard carbon steel(stainless steel is optional)

    Pressure

    DN15~DN1600 1.0,
    1.6,2.5,4.0MPa
    DN700~DN2400 0.6,
    1.0,1.6MPa

    DN15~DN600 1.0,
    1.6,2.5,4.0MPa

    DN15~DN600 1.0,1.6,2.5,
    4.0MPa DN700~DN2400 0.6,
    1.0,1.6MPa

    Please consult us if you need special pressure

    Liner

    PTFE,PU,CR,PFA,F46,IR

    Conductivity

    ≥5μs/cm(Please consult us if it is less than ≥5μs/cm)

    Electrode

    316L,Hastelloy,Ti,Ta,PT-It

    Protection Level

    IP67(For
    sensor,
    IP28 is
    optional)

    IP67

    IP67

    IP68

    IP67 IP68

    Medium Temperature

    -25℃~180℃
    (Please
    refer to liner
    material)

    -25℃~80℃(Please
    refer
    to liner material)

    -25℃~180℃
    (Please refer to
    liner material)

    Influence of Ambient
    temperature

    -25℃~60℃<±0.1%/10℃ or<±0.25%/10℃

    Repetition

    ≤±0.1%,±0.25%

    Analog output Error

    ≤±0.02mA

    Current

    ≤20m/s

    Electrical connection

    M20*1.5seal,G1/2,NPT1/2

    Output interface

    Standard output(4~20mA),Pulse output,RS485,HART,Profibus-PA



    Cheap 2 Inch Clamp Type Electromagnetic Flow Meter for Waster Water Field for sale
    Send your message to this supplier
     
    From:
    Enter your email please.
    To: Nanjing Metlan Measurement & Control Instrument Co., Ltd
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2017 xuijs.com. All rights reserved.