Categories Boiler Economizer
Brand Name: HD Boiler
Model Number: Stainless type Economizer
Certification: ISO9001 , SGS , TUV , ASME , EN
Place of Origin: China
MOQ: 1 Set / Sets 10 tons
Price: Negotiable
Payment Terms: L/C, T/T, Western Union
Supply Ability: 500 Tons per month
Delivery Time: 60 days
Packaging Details: Seaworthy packing
Material: Stainless steel
Application: Exhaust gas control
Type: Natural circulation
Usage: Heat exchange
Size: Cusomized
Port: Shanghai
Condition: New
Packing: Iron Frame Package
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Heat Exchange Boiler Economizer With H Type Or Spiral Fins TIG Argon Arc Welding


    Heat Exchange Boiler Parts Economizer With H-Type Or Spiral Fins TIG Argon-Arc Welding,ASME Standard



    Product Description


    1Economizers are mechanical devices intended to reduce energy consumption, or to perform useful function such as preheating a fluid.
    2The term economizer is used for other purposes as well. Boiler, power plant, heating, Refrigeration, ventilating, and air conditioning (HVAC) uses are discussed in this article.
    3In simple terms, an economizer is a heat exchanger.The economizer has advanced manufacturing technology, strict production technology, detection means, with high-tech snake-like tube production lines.



    Parameter


    Name(unit)Specification(mm)
    Bare pipe(OD)25-165
    Bare pipe(Thickness)2-8
    Fin (Thickness)0.6-3.0
    Fin (Height)5-30
    Fin tube thread pitch5-30
    Fin tube length≤12000


    *Note:HD BOILER can bespoke special type of economizer according to customer's requirement.


    Functions


    1.absorb the heat of low temperature flue-gas to reduce the temperature,fuel saving.

    2.Feed water is heated in econimizer before entering the evaporating heating surface,it's reduce heat absorbed of water in evaporating heating surface.Therefore,cheapr economizer surface can replace some of expensive evaporating surface,more economically.

    3.Increase the temperature of water before entering steam drum,reduce temperature difference between feed water and steam drum.Thus,the thermal stress of steam drum is reduced and entend service life.


    Details


    1Economizers must be sized for the volume of flue gas, its temperature, the maximum pressure drop allowed through the stack, what kind of fuel is used in the boiler, and how much energy needs to be recovered.
    2Economizers designed for natural gas only, would likely plug-up if installed on a coal boiler and would face increased risk of corrosion if installed on an oil-fired boiler.
    3Some units are designed to keep the flue gases above condensation temperature, and others are made of materials that resist the corrosive effect of condensed flue gases.


    Application


    1During boiler operation in typical commercial and industrial applications, approximately 10-20% of the heating value of fuel is expelled with the stack gases to the atmosphere.
    2Stack economizers are designed to recover significant amounts of this stack gas energy loss, thereby vastly improving boiler system efficiency.
    3There are several considerations when selecting an economizer
    4Gas-side Pressure Drop. Added back-pressure on the boiler stack affects the combustion air fan throughput capability. The economizer and combustion air fan(s) must be sized properly in order to assure a suitable system operation and capacity.
    5Feedwater Temperature. The feedwater to the economizer must be deaerated and the temperature setpoint minimally at 220oF to prevent tube corrosion.
    6Water-side Pressure Drop. Feedwater pumps must be sized to accommodate the economizer pressure drop. Additionally, a continuous modulating feedwater system is required to ensure proper flow rates through the economizer.


    Quality Control


    1Impact test and Strength calculation report with applied materials information.
    2100%NDT(non-destructive inspection) report of steel plate, tube and electrode.
    3X-ray, γ-ray and liquid penetrant test inspection report (welding seam): to ensure the quality of the entire boiler.
    4Hydraulic test report: ensure the standard working pressure and safety.



    Company Introduction


    Established in 1985,Zhangjiagang Hua Dong Boiler Co.,Ltd.(trading as HD Boiler),produces power plant; industrial; waste heat; waste incineration; biomass; organic heat carrier and electric steam boilers. Coupled with a comprehensive range of heating surfaces, HD Boiler brings to the market a unique service including boiler design , fabrication, installation, maintenance and replacement of boiler pressure parts.

    • Fabrication area of 400,000 square meters
    • 150 Engineers
    • 600 Coded welders
    • 60 Licensed Inspectors(NDT Level-III instructors)
    • Class-A Licenses for Design and Manufacture Boiler
    • ISO 9001:2008 Quality System
    • ASME Certificate of Power Boilers
    • ASME 'S','U' and NB stamp authorization


    Cheap Heat Exchange Boiler Economizer With H Type Or Spiral Fins TIG Argon Arc Welding for sale
    Send your message to this supplier
     
    *From:
    *To: Zhangjiagang HuaDong Boiler Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category:
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 xuijs.com. All rights reserved.