Categories | Electrical Calibration Equipment |
---|---|
Brand Name: | XL |
Model Number: | XL-9200 |
Certification: | CE |
Place of Origin: | China |
MOQ: | negotiate |
Price: | negotiate |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 800 pcs per month |
Delivery Time: | 3~4 weeks |
Packaging Details: | external packing:carton or non wooden box;cushion packing:EPE foam |
Name: | Electrical Calibration Equipment |
Accuracy level: | 0.02% |
Voltage: | 0-1000V |
power error: | 0.1% |
AC frequency range: | 0.001-5KHz |
stability: | better than 0.01% |
High Accuracy Electrical Calibration Equipment For For DC Energy Meter Verification
XL-9200 DC electric energy meter verification device is the latest
standard voltage and current source designed and developed by
Shenzhen Xinglong Technology Co., Ltd., which is based on the
current national standard for DC energy meter verification and
adopts the latest technology. The main components are imported
industrial grade devices, which can support 0~200ADC high current
signal, the accuracy level is better than 0.05%; 0~1000V DC voltage
output, accuracy grade is better than 0.02%; 0~5V DC voltage analog
shunt Output, accuracy class 0.05%, and support voltage, current
output ripple superposition function, can be used for DC load meter
virtual load verification, ripple interference test, or as a
separate voltage standard source, current standard source, power
standard source The device has passed the test of Shenzhen
Metrology Institute.
The device adopts 800×600 liquid crystal display, the interface is
clear and simple, the operation is convenient, and the visual
effect is good. The core module uses 32-bit high-speed DSP combined
with adaptive Lagrangian interpolation algorithm to eliminate the
hardware non-synchronization error of DC ripple. Waveform
quantization uses 32-bit dual modulation output technology to
ensure high output accuracy. The output has overcurrent and
overheat protection, which is safe and reliable.
Name: | Electrical Calibration Equipment | Accuracy Level: | 0.02% |
---|---|---|---|
Voltage: | 0-1000V | Power Error: | 0.1% |
AC Frequency Range: | 0.001-5KHz | Stability: | Better Than 0.01% |
1.Main functions
Main function Description
DC voltage output Supports 0~1000V DC voltage output with an
accuracy of up to two ten thousandths
DC current output Supports 0~250A DC current output with accuracy
up to five ten thousandths
Small signal output Supports 0~5V DC voltage output with accuracy
better than 5/10,000
Ripple output supports 20~500Hz ripple output
DC electric energy meter verification Supports virtual load meter
verification of DC energy meter
Error calculation Support automatic error calculation of upper
software
Start test support
Latent test support
Ripple test support
Generate report support
2.Technical indicators
No. Name Indicator range
1 Accuracy level 0.05
2 Voltage, current, small signal amplitude accuracy Voltage: 0.02%
RD + 10mV
Current: 0.05% RD+20uA
Small signal: Uo ≤ 4 mV: 0.05 % RD +10 uV;
4 mV ≤ Uo ≤ 5 V: 0.05 % RD
3 power error 0.1%
4 output phase number 1 phase voltage, 1 phase current
1 way small signal
5 gear setting voltage: 65V, 250V, 500V, 750V, 1000V
Current: 0.02A, 0.2A, 1A, 5A, 10A, 20A, 60A, 200A
Small signal: 2.5mV, 20mV, 100mV, 1V, 5V
6 Output stability Voltage: better than 0.01%, typically 0.005%
Current: better than 0.01%, typically 0.005%
Small signal: better than 0.02%
7 Output power Current: 200VA maximum, port voltage up to 2V
Voltage: up to 100VA, output current 100mA
Small signal: Uo≤1V:≤1mA
1V≤Uo≤ 5V:≤10mA
8 Ripple superposition Frequency: 20~500Hz
Ripple voltage accuracy: 20-500Hz: <0.5%
Ripple current accuracy: 20-200Hz: <1%
200-500Hz: <5%
9 Long-term stability Voltage and current: ±100PPM/year
3. Notes (Important)
l Although the device has three inspected pulse input ports, only
one of the inspected tables that are not isolated for voltage and
current input can be calibrated at a time.
l The voltage and current outputs of the device are isolated from
each other, allowing the user to have a short contact between
voltage and current during use, that is, only a single point
connection of voltage and current is allowed.
l The voltage output can be as high as 1000V, which is a threat to
personal safety. Please pay attention to safety.
![]() |
About Us
Customer Services
Sell On Us