Categories | Battery Testing Machine |
---|---|
Brand Name: | GAOGE |
Model Number: | GAG-3008 |
Certification: | CE/ISO9001 |
Place of Origin: | CHINA |
MOQ: | 1 set |
Price: | Negotation |
Payment Terms: | T/T, Western Union |
Supply Ability: | 15 sets per month |
Delivery Time: | 15 working days after received your payment |
Packaging Details: | Standard Export Wooden Case (Plywood) |
Applicable Industry: | Battery Industry |
Standard: | QC/T 743-2006,QC/T 744-2006,GB/T 31467.3-2015 |
Material: | #SUS 304 Stainless steel |
Burn time: | 0~ 999.9±0.1s |
Test cover: | Aluminum,Width of 610mm |
Power supply: | AC380V, 50Hz, 10A |
Power: | Electronic |
Company Info. |
Gaoge-Tech Instrument Co., Ltd. |
View Contact Details |
Product List |
IEC62133 Battery Pack Cell Battery External Fire Burning Testing Safety Test
Description
Battery Burning Tester is suitable for mobile phone, notebook computer and other small electronic consumer products battery fire resistance/flammability testing. This machine is to screen fixed on the above 38.1mm from the burner at the top of the screen, each 25.4mm has 20 eyelets, wire diameter 0.25mm; igniting the burner, and the burning of the battery, or until the battery explosion or battery burned, and the burning timing.
Specifications
Model | GAG-3008 |
Burner | The UL burner, caliber diameter 9.5mm or 38mm, length 100 mm |
Flaming combustion time | 0~ 999,999 seconds ±0.1second |
Flame height | 10~75±2mm |
Testing Cover Width | 24″(610mm) , octagon shape(could be customized) |
Test cover highly | 12″(305mm) (could be customized) |
Ignition devices | Automatic ignition (remote control type control 8 meters of less than effective) |
Burning gas | Propane gas, Liquefied petroleum gas or methane |
Mesh Material | Stainless steel |
Working temperature range | 0ºC~40ºC |
Power supply | AC 220V/50HZ |
Consumption | ≤300W |
Fuse | 3A |
Safety indicators | Insulation resistance: shell, power input terminal are greater than 2MΩ. |
Pressure resistance: 1 seconds resistance voltage 1750V between the input power supply and the shell, whole current 10mA | |
Grounding: the power grounding electrode, the resistance between the shells is less than 0.1Ω | |
Fire extinguisher | manual CO2 fire extinguisher |
Customized service | Welcome to Non-standard, Special requirements, OEM/ODM orders. |
Features
1. Because of the certain danger of burning test, in order to
protect, all the operation of this test should be tested in the
room separated from the observer.
2. When do flame exposure test, the test sample cell or battery
should be placed on a small wire net horizontally covered by the
test base. Before the test, adjust the position of the burner make
the wire mesh on the above 38.1mm from the burner. After adjusting
the location, ignite the flame, when the steel wire mesh is red,
use crucible clamp to hold the test sample and place it on the wire
mesh to burn until the battery explodes or burn down.
3. When do particles burning test, first remove the octagon
protection cover and the top cover, put the test sample cell or
battery on the wire net on the test base , adjust the gas and air
flow rate, make the burner produces bright blue flame and the steel
wire net burning into bright red (approximately about 700 ºC),
place the gauze screen according to standard requirement(the gauze
screen prepared test handle), burning until lithium battery
explosion or burn down.
4. When do projectile test, It is required that cover the octagon
protection cover and the top cover on the sample. The sample is
placed on the steel wire net on the top of the test base, heating
the sample until the sample explodes or the lithium burns down.
Standard
UL 2272-2016 Outline of investigation of electric balance car |
UL 2271-2013 Battery for light electric vehicle |
GB/T 31241-2014 Safety requirements for lithium ion battery and battery pack for portable electronic products |
GB/T 18287 -2013 External short circuit requirements of General specification for lithium ion batteries for cellular telephones |
GB/T 8897.4-2008 The fourth part of the primary battery safety requirements of lithium batteries |
YD/T 2344.1-2011 Lithium iron phosphate batteries for communication - part one: integrated batteries |
GB/T 31485-2015 Safety requirements and test methods for power batteries for electric vehicles |
GB/T 21966-2008 Safety requirements for lithium primary batteries and batteries in transit |
MT/T 1051-2007 Lithium ion battery for miner's lamp |
YD 1268-2003 Safety requirements and test methods for lithium batteries and chargers for mobile communication handsets |
GB/T 19521.11-2005 Safety code for inspection of hazardous properties of lithium batteries |
YDB 032-2009 Backup lithium ion battery pack for communication |
UL 1642:2012 Lithium battery standard |
UL 2054: 2012 Household and commercial storage battery |
UN38.3(2012) Recommendations on the transport of dangerous goods - Test and standard manual part 3 |
IEC62133-201 Safety requirements for battery and storage battery with alkaline |
or non acid electrolytes |
IEC 62281: 2004 Safety requirements for lithium primary batteriy and battery pack in transit |
IEC 60086: 2007 Primary battery part 4 safety requirements of lithium battery |
GJB150,GJB360,GJB548,GJB1217,MIL-STD-810F,MIL-STD-883E etc.test specification. |