Sign In | Join Free | My xuijs.com
xuijs.com
Products
Search by Category
Wholesale Marketplace
Home > Relays >

Pump Three Phase Voltage Monitoring Relay , Under Voltage Over Voltage Protection Relay

Categories Three Phase Voltage Monitoring Relay
Brand Name: Ginri
Model Number: JVR-381
Certification: ce
Place of Origin: China Wenzhou
MOQ: 20Pcs
Payment Terms: L/C, D/P, T/T, Western Union
Supply Ability: 1000PCS Per month
Delivery Time: 2-5
Packaging Details: standard packing
Input circiut =measuring ciruit: L1,L2,L3
Rated voltage: 220VAC.380VAC,440VAC,460VAC,50/60HZ
Monitoring functions: phase sequence,phase loss,overvoltage,undervoltage,phase unbalance
Delat time for overvoltage and undervoltage: 5-8s fixed
Delay time for phase loss: 1-2s fixed
Reset time: 0.5s fixed
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Pump Three Phase Voltage Monitoring Relay , Under Voltage Over Voltage Protection Relay

    Pump Three Phase Voltage Monitoring Relay , Under Voltage Over Voltage Protection Relay


    principle of low protection

    Low voltage protection of the motor This protection is often used in the motor control loops that drive the more important devices. The power of these motors is generally larger than other motors on the bus. The principle is to connect a low voltage relay in parallel with the motor trip circuit.


    The normally closed contact, and the coil of the low voltage relay is connected in parallel between the two phases of the bus that provides the three-phase power for the motor. During normal operation, the power bus voltage is normal, and the low voltage relay coil is charged and returned in a return state. When the normally closed contact is open, the trip circuit will not be connected. When the bus loses power or a fault such as grounding occurs, the bus voltage drops to the low voltage relay action value, the relay will act, the normally closed contact will close, and the trip will be turned on. Circuit, remove the motor from the busbar. When the bus voltage recovers, the low-voltage relay returns and the normally closed contact is opened so that the trip circuit is also disconnected before the motor can be restarted. Because many devices are connected to the power bus, the loss of power to the bus or the voltage drop will cause many contactor coils to be de-energized and the devices controlled by the contactors will stop running. If the bus fault release voltage gradually recovers, many devices are After a sudden outage, particularly important equipment, DC power supply controlled circuit breakers are generally used to start and stop. After the AC power supply disappears, the DC power supply is normal, so after the trip, the closing operation can still be performed again.


    If these devices are started at the same time, it is possible. Cause the bus voltage to reduce again, is not conducive to restore the normal operation of the equipment as soon as possible, so in these important large-scale equipment direct current control loop installs the low-voltage protection, first, after can guarantee the bus line breakdown eliminates, after the voltage return to normal can make these important The equipment is quickly restored to start, that is, the trip circuit is allowed to close after the trip circuit is open. Otherwise, the trip circuit is always on and is not allowed to start. Second, due to the installation of low-voltage protection, these large power devices cannot be started before the bus voltage does not return to normal. This can speed up the recovery of the bus voltage, which helps to shorten the fault time and reduce the other losses.


    Features:

    • Compact modular size
    • Three-phase monitoring of phase sequence,phase loss,over-and undervoltage and phase unbalance
    • Adjustable ober and undervoltage threshold(for JVRW)
    • Powered by the measuring circuit
    • 1C/O contact
    • 5LEDs for status indicators

    Protective Functions

    • Phase Loass(Failure)
    • Phase sequence( Reversal)
    • Phase unbalance(Asymmetry)
    • Undervoltage
    • Overvoltage

    Applications

    • Pumps
    • Fans
    • Refrigeration Units
    • Blowers
    • Motors
    • Compressors
    • Lifts,Elevators
    • Cranes
    • Mining excavators and conveyors

    ModelJVR/JVRW
    Input circuit=Measuring circuitL1,L2,L3
    Rated voltage220VAC,380VAC,440VAC,460VAC,50/60HZ
    Monitoring functions

    Phase sequence,phase loss,overvolatge,

    undervoltage,phase unbalance

    Delay time for overvoltage and undervoltage5-8s fixed
    Delay time for phase loss,phase balance,phase sequence1-2s fixed
    Reset time0.5s fixed
    IndicatorsPhase sequence,phase loss,overvoltage,undervoltage,normal
    Output contacts1 C/O
    Contact capacity3A,250VAC(resistive load)
    Degree of protectionIP20
    Working conditions-25℃~65℃,≤85%RH,non-condensing
    Mechanical durability1000000 cycles
    Dielectric strength>2KAC 1min
    Weight110g
    Dimension(HxWxD)68x30x76mm
    MountingDin Rail


    Cheap Pump Three Phase Voltage Monitoring Relay , Under Voltage Over Voltage Protection Relay for sale
    Send your message to this supplier
     
    *From:
    *To: Wenzhou Ginri Power Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category:
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们