Categories | Vehicle Testing Equipment |
---|---|
Brand Name: | Sinuo |
Model Number: | SN2110-5 & SN2110-6 |
Certification: | Calibration Certificate(cost additional ) |
Place of Origin: | China |
MOQ: | 1 Set |
Price: | Negotiable |
Payment Terms: | L/C, T/T |
Supply Ability: | 10 Sets / Month |
Delivery Time: | 30 days |
Packaging Details: | Standard Exporting Plywood Case |
Standard Applied: | IEC 62196-1 2020 |
Clause Applied: | clause 10.2, fig. 9 & fig. 10 |
Gauge A Force: | 20N |
Gauge B Force: | 1N |
Gauge A diameter: | Φ3mm |
Gauge B diameter: | Φ1mm |
Company Info. |
Sinuo Testing Equipment Co. , Limited |
Verified Supplier |
View Contact Details |
Product List |
IEC 62196-1 Gauge“A”Guage“B”for Checking Shutters 20N 1N Test Probes
Product information:
These two test gauges separately confirm to the IEC 62196-1Ed.4CDV 2020 clause 10.2, figure 9 and figure 10. The SN2211-5 test probe with 20N force and the SN2211-6 test probe with 1N force.
Technical parameters:
1. Gauge "A" with force of 20N SN2211-5
Rigid steel wire part: Φ3+0.03 0×1+0.015 0×80±0.5; end rounded: R0.2±0.05, with 20N force.
2. Gauge "B" with force of 1N SN2211-6:
Rigid steel wire part: Φ1+0.015 0×80±0.5; end rounded: R0.05, with 1N force.
No.: | Item | Specification |
1 | Gauge “A” with force of 20N SN2211-5 | Rigid steel wire part: Φ3+0.03 0×1+0.015 0×80±0.5; end rounded: R0.2±0.05, with 20N force. |
2 | Gauge “B” with force of 1N SN2211-6 | Rigid steel wire part: Φ1+0.015 0×80±0.5; end rounded: R0.05, with 1N force. |
Test procedures (Excerpt from IEC 62196-1Ed.4CDV 2020 clause 10.2):
An electrical indicator with a voltage between 40 V and 50 V
included is used to show contact with the relevant part.
Compliance is checked by inspection and for socket-outlets with a
plug completely withdrawn by applying the above gauges as follows.
The gauge according to Figure 9 is applied to the entry holes
corresponding to the live contacts and to any other opening of the
engagement surface with a force of 20 N.
The gauge is applied to the shutters in the most unfavourable
position, successively in three directions, to the same place for
approximately 5 s in each of the three directions.
During each application the gauge shall not be rotated, and it
shall be applied in such a way that the 20 N force is maintained.
When moving the gauge from one direction to the next, no force is
applied but the gauge shall not be withdrawn.
A steel gauge, according to Figure 10, is then applied with a force
of 1 N and in three directions, for approximately 5 s in each
direction, with independent movements, withdrawing the gauge after
each movement.
For socket-outlets and vehicle inlet with enclosures or bodies of
thermoplastic material, the test is made at an ambient temperature
of (35 ± 2) °C, both the socket-outlets and the gauge being at this
temperature.