Sign In | Join Free | My xuijs.com
xuijs.com
Products
Search by Category
Wholesale Marketplace
Home >

ABB AX IEC Contactor 370A AC-3 AC-1 Coil Voltage 24V 110V 230V 380V 50/60Hz

Categories Automation Control Relays
Brand Name: ABB
Model Number: AX
Certification: CE,CCC etc.
Place of Origin: China
MOQ: 1 Unit
Price: USD15~USD120(~3P/95A)
Payment Terms: T/T, Western Union
Supply Ability: 1,000pcs/month
Delivery Time: 5-8 working days or bulk order negotiate
Packaging Details: Standard export carton
Main circuit rating current: 9-370A
Electricity type: AC,AC/DC
Main circuit rating voltage: 600V,220V,380V,110V,24V
Number of pole: 3,4
Phase: 3,1Phase
Frequency: 50/60Hz
Product name: Ac Contactor CJX2N-D09,3 pole Ac Contactor
Rated current: 370A
Standard: IEC60947,EN/IEC60947-4-1
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    ABB AX IEC Contactor 370A AC-3 AC-1 Coil Voltage 24V 110V 230V 380V 50/60Hz

    ABB AX IEC Contactor 9A,12A,18A,25A,32A,40A,50A,65A,80A,95A up to 370A, AC-3 AC-1 Coil Voltage 24V,110V,230V,380V


    AX09…AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 440 V AC.

    These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.

    Benefits

    It’s quicker and easier to build DOL starters, reversing starters or star delta
    ABB starters come with connection kits to make assembly simpler and faster. The kits save time on cable preparation and eliminate fitment and wiring error risks.
    Designing contactor coils to them fit within their overall dimensions without additional space requirements.
    Built-in and add-on auxiliary contacts provide reliable low signal contacts for 12 V 3 mA.
    Protect control circuits and save space ABB’s AX range makes surge suppressors easy to snap on and connect.
    A white contact carrier ensures the contactor state is visible at all times, even with accessories mounted.


    Features

    • Use in motor control system, or used to control machines

    • A montage switches motor function

    • Type 3-phase motor control

    Standard

    • IEC 60947-4-1 and GB 14048-4

    AX09-30-10-80

    General Information

    • Extended Product Type:

      AX09-30-10-80

    • Product ID:

      1SBL901074R8010

    • EAN:

      3471522391803

    • Catalog Description:

      AX09-30-10-80 220-230V50Hz/230-240V60Hz Contactor

    • Long Description:

      AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.


    lassifications

    • Object Classification Code:

      Q

    • ETIM 6:

      EC000066 - Power contactor, AC switching

    • ETIM 7:

      EC000066 - Power contactor, AC switching

    • UNSPSC:

      39121529

    Container Information

    • Package Level 1 Units:

      1 piece

    • Package Level 1 Width:

      48 mm

    • Package Level 1 Depth / Length:

      78 mm

    • Package Level 1 Height:

      79 mm

    • Package Level 1 Gross Weight:

      0.34 kg

    • Package Level 1 EAN:

      3471522391803

    • Package Level 2 Units:

      30 piece

    • Package Level 2 Width:

      240 mm

    • Package Level 2 Depth / Length:

      295 mm

    • Package Level 2 Height:

      145 mm

    • Package Level 2 Gross Weight:

      10.2 kg

    Certificates and Declarations (Document Number)

    Technical UL/CSA

    • General Use Rating UL/CSA:

      (600 V AC) 21 A

    • Horsepower Rating UL/CSA:

      (120 V AC) Single Phase 1/2 Hp
      (240 V AC) Single Phase 1.5 Hp
      (200 ... 208 V AC) Three Phase 2 Hp
      (220 ... 240 V AC) Three Phase 2 Hp
      (440 ... 480 V AC) Three Phase 5 Hp
      (550 ... 600 V AC) Three Phase 7.5 Hp

    • Tightening Torque UL/CSA:

      Auxiliary Circuit 9 in·lb
      Control Circuit 9 in·lb
      Main Circuit 9 in·lb

    Environmental

    • Ambient Air Temperature:

      Close to Contactor for Storage -60 ... +80 °C
      Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C
      Close to Contactor without Thermal O/L Relay -40 ... +70 °C
      Near Contactor for Operation in Free Air -40 ... +70 °C

    • Climatic Withstand:

      acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II

    • Maximum Operating Altitude Permissible:

      3000 m

    • RoHS Status:

      Following EU Directive 2002/95/EC August 18, 2005 and amendment

    Technical

    • Number of Main Contacts NO:

      3

    • Number of Main Contacts NC:

      0

    • Number of Auxiliary Contacts NO:

      1

    • Number of Auxiliary Contacts NC:

      0

    • Rated Operational Voltage:

      Auxiliary Circuit 690 V
      Main Circuit 690 V

    • Rated Frequency (f):

      Auxiliary Circuit 50 / 60 Hz
      Main Circuit 50 / 60 Hz

    • Conventional Free-air Thermal Current (Ith):

      acc. to IEC 60947-4-1, Open Contactors q = 40 °C 24 A
      acc. to IEC 60947-5-1, q = 40 °C 16 A

    • Rated Operational Current AC-1 (Ie):

      (690 V) 40 °C 22 A
      (690 V) 70 °C 18 A
      (220 / 240 V) 55 °C 22 A

    • Rated Operational Current AC-3 (Ie):

      (220 / 230 / 240 V) 55 °C 9 A
      (380 / 400 V) 55 °C 9 A
      (415 V) 55 °C 9 A
      (440 V) 55 °C 9 A
      (500 V) 55 °C 9 A
      (690 V) 55 °C 7 A

    • Rated Operational Power AC-3 (Pe):

      (220 / 230 / 240 V) 2.2 kW
      (380 / 400 V) 4 kW
      (415 V) 4 kW
      (440 V) 4 kW
      (500 V) 5.5 kW
      (690 V) 5.5 kW

    • Rated Operational Current AC-15 (Ie):

      (220 / 240 V) 4 A
      (24 / 127 V) 6 A
      (400 / 440 V) 2 A
      (500 V) 2 A
      (690 V) 2 A
      (380 / 440 V) 3 A

    • Rated Short-time Withstand Current (Icw):

      at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 60 A
      for 0.1 s 140 A
      for 1 s 100 A

    • Maximum Breaking Capacity:

      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A

    • Maximum Electrical Switching Frequency:

      AC-1 600 cycles per hour
      AC-15 1200 cycles per hour
      AC-3 1200 cycles per hour
      DC-13 900 cycles per hour

    • Rated Operational Current DC-13 (Ie):

      (110 V) 1.1 A / 121 W
      (220 V) 0.55 A / 121 W
      (400 V) 2.8 A / 134 W
      (500 V) 2 A / 144 W
      (125 V) 1.1 A / 138 W
      (24 V) 6 A / 144 W
      (250 V) 0.55 A / 138 W

    • Rated Insulation Voltage (Ui):

      acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V

    • Rated Impulse Withstand Voltage (Uimp):

      6 kV

    • Maximum Mechanical Switching Frequency:

      3600 cycles per hour

    • Rated Control Circuit Voltage (Uc):

      50 Hz 220 ... 230 V
      60 Hz 230 ... 240 V

    • Operate Time:

      Between Coil De-energization and NC Contact Closing 9 ... 16 ms
      Between Coil De-energization and NO Contact Opening 4 ... 11 ms
      Between Coil Energization and NC Contact Opening 7 ... 21 ms
      Between Coil Energization and NO Contact Closing 10 ... 26 ms

    • Degree of Protection:

      acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
      acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
      acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20

    • Terminal Type:

      Screw Terminals

    Dimensions

    • Product Net Width:

      44 mm

    • Product Net Depth / Length:

      74 mm

    • Product Net Height:

      74 mm

    • Product Net Weight:

      0.326 kg

    Cheap ABB AX IEC Contactor 370A AC-3 AC-1 Coil Voltage 24V 110V 230V 380V 50/60Hz for sale
    Send your message to this supplier
     
    *From:
    *To: Wuxi Fenigal Science & Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 xuijs.com. All rights reserved.