Process Connection: NPT ¼" PN25
max flow: Water 1.6l/h
max flow 2: Air 60 L/h
Valve seat: silver
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    YOKOGAWA RAKD Small Metal ROTAMETER RAKD-41T3SS-31-VPE-E80 PTFE Valve seat silver indicator

    The short-tube Rotameter is used for measurement of low flow rates of liquids and gases. Its special application is in turbulent, opaque or aggressive mediums and under high pressure.
    The instrument is mounted in a vertical pipeline with flow direction upwards.
    A float is guided concentrically in a conic metal tube.
    The position of this float is magnetically transmitted to the indicator.
    When the process conditions change the scale needs to
    be replaced by a new one of which the values should be calculated.


    FEATURES
    •Different process connections like internal threads and flanges
    •Available with control valve (horizontal connection) or without valve (vertical connection)
    •All wetted parts of stainless steel AISI 316Ti (1.4571)
    •Measuring accuracy acc. to standard VDI/VDE 3513 sheet 2 (qG = 50 %) at calibration conditions
    •Round industrial standardized stainless steel housing
    with degree of protection IP 66/67
    •Light, guided floats resulting in low pressure loss and stable float movement
    •Max. flow range water: 1 to 250 l/h water resp.
    •Max. flow range air: 40 to 8000 l/h (+20 °C, 1.013 bar abs)
    •Turndown ratio: 10:1
    •Pressure controller for a maximum flow of 100 l/h water resp. 3.250 l/h air
    •Electronic µP-controlled transmitter with linearized output
    •Electrical connection by fast connection technique (Quickon)
    •Limit switches, also available as “fail-safe” version
    •Connection of common transformer isolated barriers and transmitter power supplies possible
    •Intrinsically safe version (Ex i): ATEX, IECEx, FM, NEPSI, PESO, EAC, INMETRO, KOSHA
    •Non-electrical hazardous area approval: ATEX and EAC
    •FMEDA report available for SIL application


    Contents
    Featurespage 1
    Standard Specificationspage 2
    Hazardous Area Specificationspage 5
    Temperature Specificationpage 8
    Installation and Planning Hintspage 9
    Model and Option Specificationspage 9
    Optionspage 14
    Dimensionspage 15
    Types of Process Connectionspage 18
    Installation Lengths depending on Process Connection Type and Sizepage 18
    Weightspage 18

    STANDARD SPECIFICATIONS
    RoHS Directive 2011/65/EU:
    RoHS conform acc. to EN 50581
    MEASURING TUBE
    Materials of wetted parts1:
    •Stainless steel AISI 316Ti (1.4571)
    •Other materials on request
    Fluids to be measured:
    Liquid or gas
    Measuring range:
    See pages 9 to 13
    Measuring turndown ratio:
    10:1
    Process connections:
    •Inner thread: G ¼"; NPT ¼"; G ⅜"; NPT ⅜"
    •Cutting ring: 6 mm; 8 mm; 10 mm; 12 mm
    •Cutting ring (Swagelok): 6 mm; 8 mm; 10 mm; 12 mm
    •Nozzle: 6 mm; 8 mm
    •Flange (screwed in):
    •Acc. to EN 1092-1:
    DN15 and DN25 PN40;
    •Acc. to ASME B 16.5:
    ½" and 1" Class 150, Class 300
    •Stainless steel AISI 316Ti Gasket PTFE
    Process pressure:
    Depends on process connection; see model code
    Viscosity limit:
    6 mPas
    Process temperature:
    •Without valve: -25 °C to +250 °C
    •With valve -25 °C to +150 °C See also fig. 2.
    Lower temperatures on request.
    Measurement accuracy:
    Acc. to standard VDI/VDE 3513 sheet 2 (qG = 50 %) 4 %
    Installation:
    •Installation position: vertical
    •Flow direction: upwards
    •Face to face length: 125 mm, with flange 250 mm
    Weight:
    See table 9
    MECHANICAL INDICATOR, type -T
    Measuring principle
    The indication is made by magnetic coupling of a magnet enclosed in the float and a magnet in the indication unit, which follows the movements of the float.
    Scale:
    Standard: removable aluminium plate with printed scale (double scale as option)
    Indicator housing:
    •Material: Stainless steel AISI304 (1.4301)
    •Degree of Protection: IP66/67
    Process and ambient temperature:
    The dependency of the process temperature from the ambient temperature is shown in fig. 2.
    Transportation and storage condition:
    -40 °C to +110 °C
    ELECTRONIC TRANSMITTER, type -E
    Temperature range:
    -25 °C to +65 °C
    Transportation and storage condition:
    -40 °C to +70 °C
    Process and ambient temperature:
    The dependency of the process temperature from the ambient temperature is shown in fig. 2.
    Power supply:
    14 to 30 V DC
    Load resistance:
    (U − 14 V) / 20 mA, max. 500 Ω
    Analog output:
    4 to 20 mA
    Linearity:
    ± 0.25 % of 20 mA
    Hysteresis:
    ± 0.15 % of 20 mA
    Repeatability:
    ± 0.16 % of 20 mA
    Influence of power supply:
    ± 0.1 % of 20 mA
    Temp. coefficient of analog output:
    ± 0.5 % / 10 °C of 20 mA
    AC-part of analog output:
    ± 0.15 % of 20 mA
    Long time stability:
    ± 0.2 % / year
    Maximum output current:
    21.5 mA
    Output current in case of failure:
    ≤ 3.6 mA (NAMUR NE 43)
    Response time (99 %):
    Approx. 1 s
    Quickon connector:
    •Cable diameter: 4 to 6 mm
    •Cable cross-section: 0.34 to 0.75 mm2
    Pulse output, option /CP:
    Electronic switch with galvanic isolation, acc. to EN 60947-5-6 (NAMUR)
    •Pulse length: 200 ms
    •Max. frequency: 4 Hz
    Electromagnetic compatibility (EMC)
    •EN 61326-1: Class A, see Table 2
    •EN 61326-2-3
    POWER SUPPLY FOR ELECTRONIC TRANSMITTER,
    option /UT
    Type:
    Power supply with galvanically separated input and output RN221N-B1, HART®-compatible
    Supply voltage:
    20 to 250 V DC / AC 50/60 Hz
    Maximum load:
    700 Ω
    Output signal:
    4 to 20 mA

    SWITCHING LEVELS FOR LIMIT SWITCHES

    Table 1 Min, Max, Min-Max, Min-Min and Max-Max-contact as standard version

    Option /K1Option /K2Option /K3

    Function


    Pointer

    SignalSignalSignal
    SC2-N0SC2-N0SC2-N0
    MAXabove LV below LV

    ----

    ----

    1 mA

    3 mA

    1 mA

    3 mA


    Function


    Pointer

    SignalSignalSignal
    SC2-N0SC2-N0SC2-N0
    MINabove LV below LV

    3 mA

    1 mA

    ----

    ----

    3 mA

    1 mA

    Note: LV = Limit Value

    Table 2 Min, Max and Min-Max-contact as fail-safe version


    Option /K6Option /K7Option /K8

    Function


    Pointer

    SignalSignalSignal
    SJ2-SNSJ2-SNSJ2-SN
    above LV----1 mA1 mA
    MAXbelow LV----3 mA3 mA
    fail-safe----1 mA1 mA

    Function


    Pointer

    SignalSignalSignal
    SJ2-SNSJ2-SNSJ2-SN
    above LV3 mA----3 mA
    MINbelow LV1 mA----1 mA
    fail-safe1 mA----1 mA
    Note: LV = Limit Value

    Cheap YOKOGAWA RAKD Small Metal ROTAMETER RAKD-41T3SS-31-VPE-E80 PTFE Valve seat silver indicator for sale
    Send your message to this supplier
     
    From:
    To: Beijing Usin Technology Co.,Ltd
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2019 xuijs.com. All rights reserved.