Sign In | Join Free | My xuijs.com
xuijs.com
Products
Search by Category
Wholesale Marketplace
Home > Other Electrical Equipment >

Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100

Categories VICTOR Digital Multimeter
Brand Name: VICTOR
Model Number: VICTOR 79
Certification: CE
Place of Origin: CHINA
MOQ: 1pcs
Price: USD200/pc
Payment Terms: T/T, Western Union, L/C, Paypal
Supply Ability: 3000pcs available
Delivery Time: 5 to 30 days
Packaging Details: 10pcs/Carton; Carton Size: 39.5*38.5*26cm; 10.2KG/carton
Color: Blue and Black
Size: 205*92*45mm
Product Name: Process Multimeter
Material: Plastic, metal, silica gel
Packing Details: 10pcs/Carton; Carton Size: 39.5*38.5*26cm
Accuracy: 0.5% accuracy
Warranty: 1 year
Weight: Approx. 500 g (including batteries)
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100

VICTOR 79 Digital Multimeter 2 In 1 4-20mA Signal Output Multimeter Process Signal Source 40MΩ RTD RSKEJTNB Cu50 Pt100


Specifications

All the speculations apply to +18℃to +28℃, 10% to 70%RH unless stated otherwise.

All speculations assume a 5- minute warm- up period.

Standard speculation is valid for one year.


DC Voltage Measurement

Range(DC V)ResolutionAccuracy,+( % of reading +counts)
4.000V0.001V0.2%+4
40.00V0.01V0.2%+4
400.0V0.1V0.2%+4

Measuring Impedance:10 MΩ(nominal),<100pF

Common mode rejection ratio: 50Hz or 60Hz > 100dB

Normal mode rejection ratio: 50Hz or 60Hz > 45dB

Overvoltage protection: 600Vp-p


DC mV Measurement

Range(DC mV)ResolutionAccuracy,+( %reading +counts)
40.00mV0.01 mV0.5%+6
400.0mV0.1 mV0.2%+4

Measuring Impedance: 10 MΩ(nominal)

Overvoltage protection: 600Vp-p


TC Measurement

Range(type)Set RangeResolutionAccuracy+(%reading +counts)
R-40~1760℃1℃

0.5%+3(≤100℃)

0.5%+2(>100℃)

S-20~1760℃1℃

0.5%+3(≤100℃)

0.5%+2(>100℃)

B400~1800℃1℃

0.5%+3(≤600℃)

0.5%+2(>600℃)

E-200~500℃1℃

0.5%+2(≤-100℃)

0.5%+1(>-100℃)

K-200~950℃1℃

0.5%+2(≤-100℃)

0.5%+1(>-100℃)

J-200~700℃1℃

0.5%+2(≤-100℃)

0.5%+1(>-100℃)

T-200~400℃1℃

0.5%+2(≤-100℃)

0.5%+1(>-100℃)

N-200~1000℃1℃

0.5%+2(≤-100℃)

0.5%+1(>-100℃)

By using ITS-90 temperature scale

Note: The accuracy does not include the error of internal temperature compensation caused by a sensor. The range of the internal temperature compensation sensor is + 2℃.


AC Voltage Measurement

Range(ACV)Resolution

Accuracy,+( %reading +counts)

40~400Hz

400.0mV0.1mV1.0%+4
4.000V0.001V0.5%+4
40.00V0.01V0.5%+4
400.0V0.1V0.5%+4

Specifications are valid from 5% to 100% of amplitude range

400mV is only confined to manual range

AC conversion: average value

Measuring Impedance: 10 MΩ(nominal),<100pF

Common mode rejection ratio: 50Hz or 60Hz > 100dB

Overvoltage protection: 600Vp-p

DC Current Measurement

Range(DC mA)ResolutionAccuracy,+( %reading +counts)
40.00mA0.01 mA0.2%+4
400.0 mA0.1 mA0.2%+4

Overload protection: 0.5A,250V fast-blow fuse

Measuring Impedance: 1Ω


AC Current Measurement

Range(AC mA)Resolution

Accuracy,+( %reading +counts)

40~400Hz

40.00mA0.01 mA0.5%+4
400.0 mA0.1 mA0.5%+4

Specifications are valid from 5% to 100% of amplitude range

Overload protection: 0.5A,250V fast-blow fuse

Measuring Impedance: 1Ω


Resistance Measurement

RangeResolutionAccuracy,+( %reading +counts)
400.0Ω0.1Ω0.2%+4
4.000kΩ0.001kΩ0.2%+4
40.00kΩ0.01kΩ0.2%+4
400.0kΩ0.1kΩ0.2%+4
4.000MΩ0.001 MΩ0.5%+4
40.00 MΩ0.01 MΩ1%+4

Open circuit voltage:0.4v

Guide lead resistance is excluded in the accuracy

Overvoltage protection: 600Vp-p


RTD Measurement

Range(type)Input RangeResolutionAccuracy,+( %reading +counts)
Pt100-200~700℃1℃0.5%+2
Cu50-50~150℃1℃0.5%+4

By using Pt100-385 temperature scale

Measuring current 1 mA

Note: attached lead resistance is excluded


Frequency Count Accuracy

RangeResolutionAccuracy,+( %reading +counts)
50.00Hz0.01Hz0.1%+3
500.0Hz0.1Hz0.1%+3
5.000KHz1Hz0.1%+3
50.00KHz0.01KHz0.1%+3
100.0KHz0.1KHz0.1%+3
Display updates 3 times/second (at >10Hz)

Diode Test and Continuity Test

Diode test indication:

Displays voltage drop across device, open circuit voltage: 1.1v-1.6v; short circuit current:<0.2 mA(typical value). Accuracy+ (2%reading +1count)

Continuity test indication:

Continuous audible tone for test resistance<50

Open circuit voltage: <0.45v

Short circuit current:130μA typical

Overload protection: 600V(peak)

Technical Data


ProjectVICTOR 77VICTOR 78VICTOR 79
MeasurementDC voltageRange±51V±400V±400V
The highest
resolution
10mV0.01mV0.01mV
Basic accuracy0.5%0.2%0.2%
AC voltageRange`510V400V400V
The highest
resolution
100mV0.1mV0.1mV
Basic accuracy1.5%0.5%0.5%
ResistanceRange5kΩ40MΩ40MΩ
The highest
resolution
0.1Ω0.1Ω
Basic accuracy0.5%0.2%0.2%
DC currentRange±22mA±400mA±400mA
The highest
resolution
1uA10uA10uA
Basic accuracy0.2%0.2%0.2%
AC currentRangeN/A400mA400mA
The highest
resolution
10uA10uA
Basic accuracy0.5%0.5%
ThermocoupleRangeN/AN/AR,S,B,E,K,J,T,N
The highest
resolution
1°C
Basic accuracy0.5%
RTDRangeN/AN/ACu50,Pt100
The highest
resolution
1°C
Basic accuracy0.5%
CAPRangeN/AN/AN/A
The highest
resolution
Basic accuracy
FrequencyN/A10Hz~100kHz10Hz~100kHz
Diode test
Continuity beeper
Data hold
Relative value measurementN/A
SourceDC voltageRangeN/A-50.0mV~550.0mV
-0.500V~5.500V
-10.00mV~110.00mV
-0.5000V~5.5000V
Resolution0.1mV,1mV0.01mV,0.1mV
Basic accuracy0.2%0.2%
ResistanceRangeN/AN/A0~400.0Ω
Resolution0.1Ω
Basic accuracy0.2%
DC currentRange22mA22mA22mA
Resolution0.001mA0.01mA0.001mA
Basic accuracy0.2%0.2%0.2%
Simulating transmitter
25%,100%Step output
Automatic rampN/A
Automatic stepN/A
Display current and % of span
Loop power24V15V15V
FrequencyN/A1.0Hz~11.0kHz1.0Hz~11.0kHz
ThermocoupleN/AN/AR,S,B,E,K,J,T,N
RTDN/AN/ACu50,Pt100
Loop detectionThe 24V loop power supply and measuring the currentN/AN/A
Built in 250 Ω
HART loop resistance
N/AN/A
Power Supply2×1.5V AA Alkaline battery4×1.5V AAA Alkaline battery4×1.5V AAA Alkaline battery
Auto Power-off
BacklightN/A
SafetyCAT Ⅳ 600V,
Pollution degree 2
CAT Ⅲ 600V ,
Pollution degree 2
CAT Ⅲ 600V,
Pollution degree 2
Size180×90×52205×95×42205×95×42
WeightAbout 400gAbout 500gAbout 500g
AccessoriesTest line, manual,fuseTest line, manual,fuseTest line, manual,fuse
Standard Quantity Per Carton10pcs10pcs10pcs
Standard Carton Measurement395mm*385mm*260mm395mm*385mm*260mm395mm*385mm*260mm
Standard Carton Cross Weight8.8Kg9.8Kg10.2Kg

Cheap Digital Multimeter  Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100 for sale
Send your message to this supplier
 
*From:
*To: XI'AN BEICHENG ELECTRONICS CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0